WARMMARK® Duo
This indicator shows for two temperatures whether and for how long the limit values have been exceeded. The WarmMark® Duo is used for products that require a known temperature range and cannot tolerate certain time/temperature combinations. The length of time during which the temperature was higher than 10 °C and temperature peaks above 34 °C are monitored.
Limit value and trigger times
Limit value |
Window 1 |
Window 2 |
Window 3 |
Window 4 |
10 °C |
3 days |
8 days |
14 days |
-- |
34 °C |
-- |
-- |
-- |
30 min. |
Product safety information
Manufacturer information:
ShockWatch Inc DBA SpotSee
5000 Quorum Drive, Suite 550
Texas
Dallas, Vereinigte Staaten, 75254
techsupport@spotsee.io
Responsible person:
Transport Control International GmbH
Am Knick 9
Schleswig-Holstein
Oststeinbek, Deutschland, 22113
info@monitoring-shop.de
- application
- self-adhesive
- Storage conditions
- Temperature below the limit values
- Shelf life
- 2 years from date of manufacture
- Release
- when the limit value is exceeded by 2 °C
- Tolerance
- +/- 1 °C
- Dimensions (L x W x H)
- 98 x 19 x 1.5 mm
WarmMark Temperature Indicator