ShockLog 248 - Electronic transport monitoring for the highest demands
The ShockLog 248 models extend the SpotSee® data logger product range. They detect critical events during the transportation, storage or use of sensitive products in different ways and with differentiated evaluation characteristics. Shocks, vibrations and environmental influences such as temperature, humidity and air pressure can cause considerable damage. The determination of certain values and the possible identification of the cause are the first promising measures to reduce transport damage and the associated costs. The preventive use of ShockLog devices to limit risks and avoid damage is the main focus of their application.
3-axis shock measuring device
2,048 samples per second per axis
Shock values up to 10/30/100 g
Internal temperature sensor
Product safety information
Manufacturer information:
ShockWatch Inc DBA SpotSee 5000 Quorum Drive, Suite 550
Dallas, Texas, Vereinigte Staaten, 75254
techsupport@spotsee.io
Responsible person:
Transport Control International GmbH Am Knick 9
Oststeinbek, Deutschland, 22113
info@monitoring-shop.de
Technical specifications, general
Dimensions
88 x 84 x 55 mm (L x W x H)
Shock measurement range
1.1 g to 100 g (depending on model)
Recording parameters
Shocks on X, Y, Z axes, Temperature
Technical data, general
Display
no
Date / Time
yes
Alarm values
yes
Status display
yes
Communication
USB, iButton
Mounting
Screws, custom
Operating range
-40 °C to +85 °C
Temperature measurement range
-40 °C to +85 °C
Temperature accuracy
±2 °C
Humidity measurement range
0 to 100 % rH
Humidity accuracy
±3% rH at 25 °C, 25% to 75% rH
Dew point
-40 °C to +85 °C
Tilt indicator
no
Resolution
0.1 %
Shelf life
unlimited
Password protection
yes
Tolerance
±2% at 5 g
Battery type
1 x 3.6 V lithium , 1 x 1.5 V AA alkaline
Battery life
up to 12 months
Memory type
Flash memory
Measurement data storage
up to 128 events per X/Y/Z axis
Sampling rate
2,048 Hz max per second
Measurement duration per burst
4–32 s
Adjustable auto-start delay
Yes
Manually adjustable start delay
No
Measurement duration
Up to 12 months
Housing
Aluminium
Protection class
IP67
Weight
445 g / without battery
Standards / Directives
EMC ETSI EN 301 489-17 v1.2.1 (2002-08) ETSI EN 301 489-1 v1.6.1 (2005-09) EN61326–1:1997 +A1:2000 +A2:2001 +A3:2003 FCC RULES CFR47: PARTS 15.109 SEPTEMBER 2007 RTCA DO-160D-Section Radiated Emissions Category B CE RoHS
Get a non-binding quote or ask our team any questions you may have about the item!
Do you need a quote for several products? Simply add the desired quantity of items to your shopping basket and request a quote. Benefit from our special conditions for corporate customers and public authorities.