MSR 175 Data Logger – Reliable Protection for Your Transports
The MSR 175 Data Logger offers precise monitoring of critical transport conditions. It reliably records physical impacts such as shocks, vibrations , temperature changes, humidity, air pressure, and light to effectively prevent transport damage and quickly resolve liability issues.
Benefits of the MSR 175 Data Logger:
Monitoring of Shocks and Vibrations: Two 3-axis acceleration sensors (±15 g and ±200 g) record up to 2,000,000 data points per transport, ensuring accurate analysis.
Versatile Applications: The MSR 175 is ideal for transporting goods in electronics, medical technology, automotive industries, and other sensitive cargo.
Temperature and Humidity Control: Records temperature fluctuations from -20°C to +65°C and humidity to ensure transport conditions are fully documented.
High Storage Capacity: The data logger can store up to 5 million shock events and other parameters, ensuring all critical events are captured.
Easy Operation and Evaluation: With the included MSR software (MSR Dashboard, ReportGenerator, and ShockViewer), the collected data can be quickly and easily analyzed.
With the MSR 175 Data Logger , you can continuously monitor your transported goods and minimize the risk of transport damage. Trust in Swiss precision and the highest reliability.
Product safety information
Manufacturer information:
MSR Electronics GmbH Mettlenstr. 6
Seuzach, Schweiz, 8472
info@msr.ch
Responsible person:
Transport Control International GmbH Am Knick 9
Oststeinbek, Deutschland, 22113
info@monitoring-shop.de
General Specifications
Storage Capacity
over 2,000,000 measured values
Medium
Air
Color
Amber
Button
Start measurement/Check status
Power Supply
Choice of Lithium-Polymer battery 230 mAh, rechargeable via USB connection, recording duration up to 8 weeks, or replaceable Li-SOCI2 battery (3.6 V, 7700 mAh), battery life at least 2 years
Options
Charging station (USB hub) for 7 MSR175 (Item number B47002)
Interface
USB
Software Package
MSR175 Dashboard Software, MSR Report Generator, free MSR ShockViewer Basic Version. Paid MSR ShockViewer Pro Version available at a later time
PC Requirements
Windows 7 or later, USB interface
Operating Conditions Specifications
Temperature
-20 to +65 °C
Optimal Storage Conditions Specifications
Temperature
+5 °C to +45 °C
Humidity
10 - 95 % relative humidity, non-condensing
Standards Specifications
Complies with EU Directive RoHS/WEEE
Internal Sensor Specifications
3-axis Acceleration Sensor
Measurement Range: ±15 g and ±200 g (-20 to +65 °C). Accuracy (Max Deviation): ±15 g Sensor: ±0.15 g (0 to 5 g, +25 °C), ±0.3 g (5 to 15 g, +25 °C)
3-axis Acceleration Sensor
Measurement/Storage Rate: 1600/s (±15 %). Accuracy (Max Deviation): ±200 g Sensor: ±2 g (0 to 15 g, +25 °C), ±5 g (15 to 100 g, +25 °C), ±10 g (100 to 200 g, +25 °C). Measurement/Storage Rate: 3200/s (±15 %), 6400/s (±15 %)
Temperature
-20 to +65 °C. Accuracy: ±0.5 °C (-10 to +65 °C). Measurement/Storage Rate: every 10 minutes
Relative Humidity
0 - 100 % relative humidity (-20 to +65 °C). Accuracy: ±2 % relative humidity (10 to 85 %, 0 to +40 °C) | ±4 % relative humidity (85 to 95 %, 0 to +40 °C). Storage Rate: every 10 minutes
Air Pressure
0 to 2000 mbar absolute (-20 to +65 °C). Accuracy: ±2.5 mbar (750 to 1100 mbar absolute, +25 °C). Storage Rate: every 10 minutes
Light
0 to 83,000 lx. max. Sensitivity at 550 nm. Storage Rate: every 10 minutes